Planning estimate

Office Network & Structured Cabling Planner

Estimate preliminary data drops, switch-port needs, wireless design status, and MDF/IDF planning questions for a new office, remodel, expansion, warehouse, or network refresh.

Echelon Technologies provides structured cabling, network infrastructure, Wi-Fi, fiber, security cameras, access control, VoIP, AV, and managed IT services for businesses.

Project Profile

Start with the facility and business-use assumptions.

Devices And Drops

Enter known devices. Edit assumptions where devices may share, need multiple drops, or need onsite validation.

Network Rooms And Existing Cabling

Capture what is known about MDF/IDF rooms, uplinks, and reuse.

Editable Drop Assumptions

Adjust the preliminary scope instead of assuming every device has the same cabling requirement.

20%
20%
Preliminary scope

Preliminary Cabling & Network Plan

The rows below show how the estimate is assembled. Edit the assumptions above to match the project instead of relying on a one-size-fits-all device count.

Facility/project information

Facility type
Office
Square footage
7,500 sq ft
Floors
1
Employees/users
45
Existing cabling
Some existing cabling may be reused
Future-growth allowance
20% (14 spare/future drops)

Device counts

Workstations
42
Offices
8
Meeting rooms
3
Printers/copiers
2
VoIP phones
35
Wireless access points
Wireless survey/design required
Security cameras
8
Access-control doors
2
Other Ethernet devices
4
Planning categoryDropsAssumption shown
Workstation/data drops4242 workstations x 1 data drop(s), plus 8 offices x 0 additional office drop(s).
VoIP phone drops0Phones are set to share physical drops with computers where practical; only phones beyond the workstation count are added as separate drops.
Printers/copiers22 device(s) x 1 drop(s).
Wireless access points0AP count is unknown, so no AP drops are invented. Wireless survey/design required.
Security cameras88 camera(s) x 1 drop(s).
Access-control equipment22 door(s) x 1 drop(s).
Conference-room/AV connections123 room(s) x 4 connection(s).
Other network devices44 device(s) x 1 drop(s).
Spare/future-capacity drops1420% of preliminary copper drops.

MDF/IDF Considerations

  • Network/IT rooms or IDFs entered: Not confirmed. Exact MDF and IDF placement should be validated with the floor plan and onsite pathways.
  • Confirm that the main network-room location supports practical cable pathways, rack space, patch panels, UPS/power, cooling/environment needs, and service access.
  • Copper-distance limitations should be checked during design; long runs may require an IDF, pathway change, or fiber uplink strategy.
  • The Internet/ISP demarcation location should be identified early so handoff cabling, firewall placement, and network-room layout can be planned.

Fiber/Uplink Considerations

  • Fiber uplink requirements are unsure; validate whether network rooms, floors, distance, bandwidth, or future expansion require fiber.
  • Do not finalize copper or fiber quantities until pathways, floor plans, network-room locations, and existing cabling conditions are confirmed.

Items Requiring Onsite Validation

  • Floor plan, furniture plan, and final workstation locations
  • MDF/main network-room location and any IDF/network closet locations
  • Cable pathways, sleeves, conduit, ceiling access, firestopping, and distance limits
  • Existing cabling condition, labeling, category rating, test results, and reuse potential
  • Patch panels, racks, UPS/power, cooling/environment, grounding, and ISP demarcation
  • Wireless survey/design, camera views, access-control door hardware, and conference-room AV requirements

Planning Questions And Guidance

Wireless design

AP quantity is not calculated from square footage alone. A design should consider the floor plan, wall construction, ceiling height, user/device density, interference, application needs, and RF conditions.

MDF and IDFs

Network-room placement should be validated against pathways, copper-distance limits, rack space, patch panels, UPS/power, cooling, service access, and the ISP demarcation.

Low-voltage systems

Security cameras, access-control doors, AV, phones, and specialty devices may need different cabling paths, mounting details, power, and switch planning.

Existing cabling

Reuse decisions should be based on cable category, labeling, pathway condition, test results, location, capacity, and whether the old layout matches the new floor plan.